Alarm rationalization is the ISA-18.2 workshop that records consequence, response time, and priority on each configured alarm. Not automatic priority.
An Alarm Register is one row per configured alarm: tag, type, setpoint, priority, P&ID, area. Master list for an ISA-18.2 workshop, not a live summary.
A signal type that reads a continuous process variable, typically 4–20 mA, into a controller.
A continuous output signal a controller uses to position a device such as a control valve.
A cable schedule lists each field cable: ID, from, to, cores, loop tag. One row per cable, not per signal. Not tray-fill or 3D routing.
A two-state input carrying a status, such as a switch or alarm contact.
A two-state output used to energise a solenoid, lamp, or motor starter.
EEMUA 191 is the UK-origin alarm-systems guide used with ISA-18.2 / IEC 62682. SchematicForge counts chatter from your CSV — not a live KPI.
A printed wire marker, usually a sleeve, whose text matches the wire number on both ends of the conductor.
A wire list of each conductor, source pin, destination pin, colour, and cable. Paid packs export a project CSV, one row per core hop.
A reference designation standard for industrial systems. SchematicForge keeps the tags you supply; it does not retag the plant to 81346.
The instrument index is the tag census (tag, service, P&ID). It is not the Loop Register and not the IO list organised by signal.
The spreadsheet of instrument tags and I/O types that drives loop diagrams, the register, and the schedules.
ANSI/ISA-18.2 (IEC 62682) is the process-industry alarm-management lifecycle. SchematicForge issues a register and workbook from your list — not a live DCS.
ISA-5.4 is the instrument loop diagram standard: one tag, field to controller. Not ISA-5.1 tagging and not a certificate.
Junction box — a field enclosure where instrument cables terminate before running back to the marshalling area.
The complete instrument circuit from field device to controller: sensors, transmitters, cables, terminations, and the controller channel.
A loop check is site verification on a loop check sheet (as-found / as-left). It is not a loop diagram and not a signed FAT certificate.
An instrument loop diagram (loop drawing) shows one tag from field device through JB and marshalling to the controller card. Not a P&ID.
The cabinet in the control room where field cables terminate and are jumpered to controller I/O cables.
Marshalling strip: terminals in the marshalling cabinet where a field cable lands before the I/O card. Not the field junction box.
A table of controller tag names, data types, and descriptions exported from the IO list so PLC tags match the loop drawings.
The engineering-unit values mapped to the bottom and top of a signal span, e.g. 0–10 bar.
A version letter or number on a drawing. Changing a loop creates a new revision rather than overwriting the old one.
One input or output within a loop. A loop can carry several signals, each with its own cable, card, and channel.
The unique identifier of an instrument, e.g. PT-1001 for pressure transmitter 1001.
A termination list is one row per signal: tag, JB terminals, marshalling terminals, wire number. A termination diagram is the same path on the loop sheet.
The boxed area of a drawing carrying project, tag, drawing number, and revision information.
The supply voltage of a loop, such as 24 VDC, governing device and barrier selection.
The wire number is printed on the conductor, the loop sheet, and the ferrule. Stored per signal; duplicates inside a loop are flagged.