Free PLC tag list from an IO list

By a practising automation / electrical engineer with more than ten years · Updated 2026-11-22

Paste up to 10 signals. Download a CSV of PLC tag names, BOOL/REAL types, and descriptions. No account. This is not a controller program and not a Studio 5000 L5X. A paid pack issues the full tag list (CSV, Excel, tags-only L5X) from the same IO list as the loop diagrams.

Loop tagSignal typeRoleDescriptionPLC type
REAL
BOOL
—
—
—
—
—
—
—
—

Unknown signal types are omitted, not guessed. Addresses are not invented. What is a PLC tag list · Allen-Bradley IO lists.

CSV columns: Tag, Type, Description, Loop, SignalType, Role.

What a PLC tag list is

A PLC tag list is the table of controller tag names, data types, and descriptions that a programmer imports so the program references match the loop drawings. One row per signal: the loop tag, whether it is BOOL or REAL, and a description an operator will recognise.

Type follows the signal. A 4–20 mA analog input or output is REAL; a limit switch, solenoid, or motor status is BOOL. Keeping that mapping consistent is what lets the same IO list drive both the field drawings and the controller tag database.

What this tool exports

This browser tool is the ten-row slice: paste up to ten signals and download a CSV of PLC tag names, BOOL/REAL types, and descriptions. Unknown signal types are omitted rather than guessed, and controller addresses are not invented — if a node, card, slot, or channel is not in the source list, it is left out.

It is not a controller program and not a Studio 5000 L5X. The paid pack issues the full tag list from the same IO list as the loop diagrams, including CSV, Excel, and a tags-only L5X export with no rungs. Import it into an empty or dedicated tag scope.

From IO list to controller

The tag list inherits everything from the IO list: the tag, the signal type, and the description. Because it is generated from the same rows as the drawings, a Rev B that changes a signal type propagates to the tag list and the loop sheet together, instead of the two drifting apart.

If you are preparing the source data, the PLC tags from an IO list guide and the Allen-Bradley IO list guide cover the column choices a controller import expects.

Frequently asked questions

Is this a Studio 5000 L5X export?

The free tool is CSV only. The paid pack adds an L5X that contains tags and descriptions but no rungs — it is not a program.

How is BOOL or REAL decided?

From the signal type. Analog 4–20 mA signals are REAL; discrete inputs and outputs are BOOL. Unknown types are omitted, not guessed.

Does it invent controller addresses?